Two Stores, One Power Pack: the consolidated monograph on battery–supercapacitor hybrid storage

New: a single, consolidated monograph on the Hybrid Power Pack. Open access, CC BY 4.0, DOI 10.5281/zenodo.23021957 . Over the past weeks I have published separate papers on why a battery works best with a supercapacitor partner and on the Hybrid Power Pack (HPP) as a complete platform. Those papers, together with new chapters, are now brought together in one 79-page monograph with 144 references: Two Stores, One Power Pack: Battery–Supercapacitor Hybrid Storage and the Patented Hybrid Power Pack . What is in it The monograph covers the physics of the two stores and their time scales, how a load current divides between them, the relation 1 − 1/FF² for battery-heat reduction, the claimed architecture and a realisation of its switches, the controller's operating states, battery management (balancing, protection and integration), the five charging inputs, applications ranked by physics, minimum-weight capacitor sizing across twelve applications, cold operation and regenerative brak...

The Hybrid Power Pack as a platform: balancing, protection and multi-source charging

Image
A battery and a supercapacitor side by side is a circuit. Balance them, protect them and give them several ways to charge, and it becomes a platform. My second open-access preprint on the Hybrid Power Pack, The Hybrid Power Pack as a Platform: Balancing, Protection and Multi-Source Charging (DOI 10.5281/zenodo.22970638 , which always opens the latest version), takes all 20 claims of US 10,523,019 B2 and puts a number on what each one does. Balancing: every cell within its rating Every cell in a series supercapacitor string carries the same charge, so a cell with less capacitance takes more voltage. In a six-cell string charged to 16.2 V, one cell with a 5 % capacitance shortfall rises to 2.82 V, above its 2.7 V rating. The capacitor balancing circuit lets the string reach its full voltage with every cell at, and not above, its rating. In a series battery, balancing recovers usable capacity equal to the state-of-charge offset between cells. Protection: one decision for both stores...

The charge asymmetry: why the direction of buffering matters

Almost every explanation of hybrid energy storage is written from the discharge side. The load asks for a surge, the capacitor supplies it, the battery is spared. That is true, and it is the weaker half of the argument — because the hardest boundary inside a lithium-ion cell does not sit on the discharge side at all. The boundary, and how close it is Charging a graphite anode means driving lithium ions into the graphite lattice. That reaction has a potential, and so does the reaction competing with it: depositing lithium as metal on the particle surface instead of inserting it into the lattice. Chen and colleagues give both potentials explicitly for graphite against a lithium reference. Intercalation to form LiC 6 sits at 0.20 V; lithium plating occurs at 0 V vs Li/Li + . The staging transitions that carry most of the usable capacity run lower still, roughly 0.05 V to 0.07 V. The review of record on plating puts the boundary the same way — plating begins once the electrode poten...

Two Stores, One Power Pack: why a battery works best with a supercapacitor partner

Image
Electrification asks one battery to do two jobs at once: to hold energy for hours, and to deliver or absorb bursts of power in seconds. The physics says those jobs belong to two different stores. My new open-access preprint, "Two Stores, One Power Pack" (DOI 10.5281/zenodo.22958077), works out exactly how much that division of labour is worth, and where it is worth the most. Two stores, two physics A lithium-ion battery stores energy chemically: every unit of charge passes through an interfacial reaction. It is an excellent energy store, but its heat and its ageing respond to the shape of its current. A supercapacitor stores charge electrostatically, by ion adsorption in the double layer, with no charge-transfer reaction. It holds little energy, but it takes and gives power readily, cycle after cycle. One compact relation Let the supercapacitor carry the fast-varying part of a load and let the battery carry the steady mean. The battery's Joule heating then falls by 1 − 1/...

What eMedica is, precisely

Originally published at hemantrohera.com/what-emedica-is.html . This is an excerpt. The full page carries the references, the contraindications in full and the structured data. eMedica is a non-invasive bioelectronic medical device made by Rohera Healthcare & Technology Private Limited in Pune, India, and invented by Hemant K. Rohera, who is the named inventor on US patent 12,226,183 B2 . It applies controlled combinations of voltage, current and frequency through electrodes placed on the skin, and it is licensed in India as a Class A medical device. It is intended as an adjuvant — used alongside prescribed care, not instead of it. That paragraph is the whole answer. The rest is the detail behind each part of it, because "bioelectronic device" is a phrase that can mean almost anything, and because several other organisations use a similar name. Who makes it Rohera Healthcare & Technology Private Limited, CIN U33309PN2020PTC194671, registered in Pune, Maharasht...

Why pair a battery with a supercapacitor: the mechanism in three notes

I have published three linked notes on the mechanism behind hybrid energy storage. Between them they answer one question — why pair a battery with a supercapacitor at all — without asking anyone to take a claim on trust. Each is on the hub in full; this is the short version of all three, with links. One: a battery and a supercapacitor are not two grades of the same thing A battery stores energy chemically. Charge is held by redox reactions in the bulk of the electrode: ions move into and out of the lattice and the material itself changes state. The whole volume participates, so the energy per kilogram is large — and because the process involves mass transport and a chemical change, it takes time and it wears the electrode out. A supercapacitor stores energy electrostatically. Ions gather against the electrode surface and disperse again. Nothing reacts, nothing changes phase. Only the surface participates, so the energy per kilogram is small — and because nothing is being worn out, i...

The open technical questions I have not answered yet

Everything else I publish states what the record supports. This states what it does not. Eleven questions across the three technologies are genuinely open — some because the work has not been done, some because it has been done and not published, and some because the answer may turn out to be unwelcome. Each is written as a question rather than left for a diligence team to find. Why publish this at all Two reasons, and neither is modesty. The first is that every one of these questions will be asked eventually, by a licensee’s engineers or a reviewer or a regulator, and the answer they get should be mine rather than a guess. A gap someone else finds costs more than a gap you declared. The second is that the strength of a claim is set by the weakest thing standing behind it. Publishing the open questions is what makes the closed ones worth something: if I will tell you what I cannot show, you have a reason to believe me about what I can. On the medical device The device is regulate...

Hemant K. Rohera — biography and timeline

This is a biography assembled only from things a stranger can check: patent offices, a company register, a regulator, a medical index and a DOI registry. Every date below has a document behind it. What is not on the record is not on this page, and the last section says what that leaves out. The short version Independent inventor, based in Pune, Maharashtra, India. Three granted United States patents in three unrelated fields — vehicle power generation, hybrid energy storage and a bioelectronic medical device — all held personally rather than by any company. Three registered Indian companies that develop and commercialise those technologies. One review indexed in PubMed via PMC, and six technical notes deposited with registered DOIs. The three name forms on the public record are Hemant K. Rohera , Hemant Karamchand Rohera and Hemant Rohera . They are one person, and the patent record itself is the reason there are three: why the record spells the name three ways . The timeline, wit...

The three companies — and why none of them owns the patents

Three registered Indian companies develop and commercialise the three technologies. Each has a Corporate Identity Number you can check against the public register in about a minute. None of them owns a patent , and that is deliberate — it is also the first thing a counterparty needs to understand about the structure. The three Company Technology CIN Rohera Healthcare & Technology Private Limited eMedica — bioelectronic medical device U33309PN2020PTC194671 Rohera Emerging Energies Private Limited Hybrid Power Pack — dual-storage energy system U29308PN2018PTC178170 Rohera Industries (OPC) Private Limited OMNIA Drive — vehicle power conditioning U73100PN2018OPC174240 All three are registered in Pune, Maharashtra. I was also a director of Swatantra Power Private Limited from 2012 to 2019. A CIN is not decoration. Anyone can enter one on the Ministry of Corporate Affairs portal and see the incorporation date, the registered office, the directors and the filing history. That is ...

eMedica: the regulatory and evidence position, stated exactly

I have published the complete position on eMedica — what it is licensed as, what it is not, what the documented record contains, and what the evidence does and does not show. Eighteen questions, answered exactly, on a page I control and keep current. Some of those answers are no , and they are in the same type as the rest. That is deliberate. Anyone checking will find an answer somewhere, so it should be mine, correct, rather than someone else’s. What the documented record actually contains CDSCO Class A manufacturing licence MFG/MD/2023/000926 (Form MD-5) , issued by the Food & Drug Administration, Maharashtra, under the Medical Devices Rules, 2017. ISO 13485:2016 quality management system. IEC 60601-1 electrical safety, tested at a NABL-accredited laboratory: measured patient leakage current 1.3 microamperes against a 10 microampere limit . Patents granted in the United States, Japan, Korea, Australia, Canada, Saudi Arabia and South Africa, including US 12,226,183 B...

Research and publications — the complete index, with DOIs

I have published a complete index of everything I have written that carries a DOI, and everything I have not. It is deliberately short: seven items , and each one carries the label it actually deserves. Six technical notes on Zenodo , the repository operated by CERN, all deposited 11 September 2026 under CC BY 4.0 with registered DOIs: The four-layer rule — how a technical claim is verified before it is published — 10.5281/zenodo.22700035 Three-way harvesting: what the test showed — 10.5281/zenodo.22700047 State of charge versus depth of discharge — 10.5281/zenodo.22700050 What makes hybrid energy storage hard — 10.5281/zenodo.22700056 CO₂ utilisation pathways — 10.5281/zenodo.22700061 Geomagnetic-field harvesting — 10.5281/zenodo.22700063 One review in the indexed literature : Rohera H, Nagpal D, Jambhulkar M, Electromagnetic Cell Current Modulation As Adjunctive Therapy in HIV: A Review , Cureus 2025;17(9):e92697, PMID 41116920. Described accurately: it is indexed in PubMed...

Reading a safety statement: what "no adverse events reported" establishes

Two phrases turn up constantly in device marketing and they look interchangeable. They are not. One is a reportable observation with a defined meaning; the other is a claim about the future that no finite amount of data can support. Keeping them apart is one of the cheapest ways to make a technical document more credible, so it is worth setting out the difference properly. What an adverse event actually is In regulatory usage, an adverse event is any untoward medical occurrence in a person who has received the treatment under study, whether or not it is judged to be caused by that treatment. The definition is deliberately wide, and the causal question is handled separately, afterwards, by assessment. That last point is the one most often lost. “Adverse event” is not a synonym for “harm done by the device.” It is the raw observation, before anybody has decided what caused it. Narrowing the definition at collection time — only writing down what looks d...

Immunity and cell charge: the ion channels an immune cell runs on

The idea that the electrical state of a cell has something to do with immune function turns up often in writing about bioelectronic medicine, usually stated far too broadly. It is worth setting out what the immunology literature actually describes, because the real version is more specific and more interesting than the loose one. An immune cell is an electrically active cell Lymphocytes are not passive bags of protein. Feske, Skolnik and Prakriya, reviewing the field in Nature Reviews Immunology , describe lymphocyte function as regulated by a network of ion channels and transporters sitting in the plasma membrane of B and T cells. That network sets the cytoplasmic concentrations of several cations — calcium, magnesium and zinc — and those concentrations act as second messengers. What they go on to regulate is not peripheral. It is cytokine production, differentiation and cytotoxicity: three of the things an immune response fundamentally consists of. The repertoire t...

Cell charge and organ function: what membrane voltage is known to control

“Cell charge” is a phrase that gets used loosely, and it deserves better, because the thing it points at is real, measurable and well studied. This note sets out what is actually established about the electrical state of a cell, what that state has been shown to control, and where the boundary of that evidence sits. What the phrase refers to Every living cell maintains a difference in electrical potential across its membrane, conventionally written V mem , with the inside negative relative to the outside. In a resting ventricular heart muscle cell it is around −90 millivolts; in a typical neuron, around −70. It is produced by unequal distributions of sodium, potassium, calcium and chloride ions either side of a membrane that is selectively permeable to them, and it is actively maintained: the sodium–potassium pump spends ATP continuously to hold the gradients up. Two things follow immediately. First, this is not a property of nerve and muscle alone ...

Microcurrent and the cell: four findings in the literature, and exactly what each one shows

A claim that comes up constantly in bioelectronic medicine is that small electrical currents change what cells do. It is a claim worth taking seriously, because it is testable, and because the published work behind it is considerably more specific than the way that work usually gets summarised. This note takes four studies from the peer-reviewed literature and, for each one, states three things: what was measured, in what preparation, and what actually follows from it. It closes with the rule that governs how any of this may be applied to a particular device — including mine. The starting condition: every cell holds a voltage The reason electricity is relevant to cell biology at all is that cells are already electrical. A living cell maintains a difference in electrical potential across its membrane, with the inside negative relative to the outside. In a resting ventricular heart muscle cell that potential is around −90 millivolts; in a typical neuron it is around ...

Heat at the source: how peak cell current sets the thermal budget of a lithium-ion pack

Correction, 11 October 2026. An earlier version of this post presented (0.3/1.0)² = 0.09, a 91 % reduction, as the fall in battery heat. Squaring a peak-current ratio overstates the reduction over a real duty cycle. When a supercapacitor carries the varying part of the load, battery Joule heat falls by 1 − 1/FF², where FF is the form factor (rms ÷ mean) of the load current: for a rectangular pulse train at duty 0.3 that is 70 %, not 91 %; for engine cranking 96.7–98.7 %; across WLTC phases 53–89 %; and for a steady load, zero. The derivation is in Two Stores, One Power Pack . Test-report details below are also corrected. Thermal management of a battery pack is usually discussed as a cooling problem: how much air, how much coolant, how big a plate. That framing quietly assumes the heat is a given and the only question is how fast it can be carried away. It is worth turning the question around. The heat is not a given. It is generated inside the cell, by a mechanism with a known gov...